pyidf.heat_recovery module¶
Data objects in group “Heat Recovery”
-
class
pyidf.heat_recovery.HeatExchangerAirToAirFlatPlate¶ Bases:
pyidf.helper.DataObjectCorresponds to IDD object HeatExchanger:AirToAir:FlatPlate Flat plate air-to-air heat exchanger, typically used for exhaust or relief air heat recovery.
-
availability_schedule_name¶ field Availability Schedule Name
Availability schedule name for this system. Schedule value > 0 means the system is available.If this field is blank, the system is always available.Parameters: value (str) – value for IDD Field Availability Schedule Name Raises: ValueError– if value is not a valid valueReturns: the value of availability_schedule_name or None if not set Return type: str
-
economizer_lockout¶ field Economizer Lockout
Yes means that the heat exchanger will be locked out (off)when the economizer is operating or high humidity control is activeDefault value: YesParameters: value (str) – value for IDD Field Economizer Lockout Raises: ValueError– if value is not a valid valueReturns: the value of economizer_lockout or None if not set Return type: str
-
flow_arrangement_type¶ field Flow Arrangement Type
Parameters: value (str) – value for IDD Field Flow Arrangement Type Raises: ValueError– if value is not a valid valueReturns: the value of flow_arrangement_type or None if not set Return type: str
-
name¶ field Name
Parameters: value (str) – value for IDD Field Name Raises: ValueError– if value is not a valid valueReturns: the value of name or None if not set Return type: str
-
nominal_electric_power¶ field Nominal Electric Power
Units: WIP-Units: WParameters: value (float) – value for IDD Field Nominal Electric Power Raises: ValueError– if value is not a valid valueReturns: the value of nominal_electric_power or None if not set Return type: float
-
nominal_secondary_air_flow_rate¶ field Nominal Secondary Air Flow Rate
Units: m3/sParameters: value (float or “Autosize”) – value for IDD Field Nominal Secondary Air Flow Rate Raises: ValueError– if value is not a valid valueReturns: the value of nominal_secondary_air_flow_rate or None if not set Return type: float or “Autosize”
-
nominal_secondary_air_inlet_temperature¶ field Nominal Secondary Air Inlet Temperature
Units: CParameters: value (float) – value for IDD Field Nominal Secondary Air Inlet Temperature Raises: ValueError– if value is not a valid valueReturns: the value of nominal_secondary_air_inlet_temperature or None if not set Return type: float
-
nominal_supply_air_flow_rate¶ field Nominal Supply Air Flow Rate
Units: m3/sDefault value: “Autosize”Parameters: value (float or “Autosize”) – value for IDD Field Nominal Supply Air Flow Rate Raises: ValueError– if value is not a valid valueReturns: the value of nominal_supply_air_flow_rate or None if not set Return type: float or “Autosize”
-
nominal_supply_air_inlet_temperature¶ field Nominal Supply Air Inlet Temperature
Units: CParameters: value (float) – value for IDD Field Nominal Supply Air Inlet Temperature Raises: ValueError– if value is not a valid valueReturns: the value of nominal_supply_air_inlet_temperature or None if not set Return type: float
-
nominal_supply_air_outlet_temperature¶ field Nominal Supply Air Outlet Temperature
Units: CParameters: value (float) – value for IDD Field Nominal Supply Air Outlet Temperature Raises: ValueError– if value is not a valid valueReturns: the value of nominal_supply_air_outlet_temperature or None if not set Return type: float
-
ratio_of_supply_to_secondary_ha_values¶ field Ratio of Supply to Secondary hA Values
Ratio of h*A for supply side to h*A for exhaust sideParameters: value (float) – value for IDD Field Ratio of Supply to Secondary hA Values Raises: ValueError– if value is not a valid valueReturns: the value of ratio_of_supply_to_secondary_ha_values or None if not set Return type: float
-
secondary_air_inlet_node_name¶ field Secondary Air Inlet Node Name
Parameters: value (str) – value for IDD Field Secondary Air Inlet Node Name Raises: ValueError– if value is not a valid valueReturns: the value of secondary_air_inlet_node_name or None if not set Return type: str
-
secondary_air_outlet_node_name¶ field Secondary Air Outlet Node Name
Parameters: value (str) – value for IDD Field Secondary Air Outlet Node Name Raises: ValueError– if value is not a valid valueReturns: the value of secondary_air_outlet_node_name or None if not set Return type: str
-
supply_air_inlet_node_name¶ field Supply Air Inlet Node Name
Parameters: value (str) – value for IDD Field Supply Air Inlet Node Name Raises: ValueError– if value is not a valid valueReturns: the value of supply_air_inlet_node_name or None if not set Return type: str
-
supply_air_outlet_node_name¶ field Supply Air Outlet Node Name
Parameters: value (str) – value for IDD Field Supply Air Outlet Node Name Raises: ValueError– if value is not a valid valueReturns: the value of supply_air_outlet_node_name or None if not set Return type: str
-
-
class
pyidf.heat_recovery.HeatExchangerAirToAirSensibleAndLatent¶ Bases:
pyidf.helper.DataObjectCorresponds to IDD object HeatExchanger:AirToAir:SensibleAndLatent This object models an air-to-air heat exchanger using effectiveness relationships. The heat exchanger can transfer sensible energy, latent energy, or both between the supply (primary) and exhaust (secondary) air streams.
-
availability_schedule_name¶ field Availability Schedule Name
Availability schedule name for this system. Schedule value > 0 means the system is available.If this field is blank, the system is always available.Parameters: value (str) – value for IDD Field Availability Schedule Name Raises: ValueError– if value is not a valid valueReturns: the value of availability_schedule_name or None if not set Return type: str
-
economizer_lockout¶ field Economizer Lockout
Yes means that the heat exchanger will be locked out (off)when the economizer is operating or high humidity control is activeDefault value: YesParameters: value (str) – value for IDD Field Economizer Lockout Raises: ValueError– if value is not a valid valueReturns: the value of economizer_lockout or None if not set Return type: str
-
exhaust_air_inlet_node_name¶ field Exhaust Air Inlet Node Name
Parameters: value (str) – value for IDD Field Exhaust Air Inlet Node Name Raises: ValueError– if value is not a valid valueReturns: the value of exhaust_air_inlet_node_name or None if not set Return type: str
-
exhaust_air_outlet_node_name¶ field Exhaust Air Outlet Node Name
Parameters: value (str) – value for IDD Field Exhaust Air Outlet Node Name Raises: ValueError– if value is not a valid valueReturns: the value of exhaust_air_outlet_node_name or None if not set Return type: str
-
frost_control_type¶ field Frost Control Type
Default value: NoneParameters: value (str) – value for IDD Field Frost Control Type Raises: ValueError– if value is not a valid valueReturns: the value of frost_control_type or None if not set Return type: str
-
heat_exchanger_type¶ field Heat Exchanger Type
Default value: PlateParameters: value (str) – value for IDD Field Heat Exchanger Type Raises: ValueError– if value is not a valid valueReturns: the value of heat_exchanger_type or None if not set Return type: str
-
initial_defrost_time_fraction¶ field Initial Defrost Time Fraction
Fraction of the time when frost control will be invoked at the threshold temperature.This field only used for exhaust air recirc and exhaust-only frost control types.Units: dimensionlessDefault value: 0.083value <= 1.0Parameters: value (float) – value for IDD Field Initial Defrost Time Fraction Raises: ValueError– if value is not a valid valueReturns: the value of initial_defrost_time_fraction or None if not set Return type: float
-
latent_effectiveness_at_100_cooling_air_flow¶ field Latent Effectiveness at 100% Cooling Air Flow
Units: dimensionlessvalue <= 1.0Parameters: value (float) – value for IDD Field Latent Effectiveness at 100% Cooling Air Flow Raises: ValueError– if value is not a valid valueReturns: the value of latent_effectiveness_at_100_cooling_air_flow or None if not set Return type: float
-
latent_effectiveness_at_100_heating_air_flow¶ field Latent Effectiveness at 100% Heating Air Flow
Units: dimensionlessvalue <= 1.0Parameters: value (float) – value for IDD Field Latent Effectiveness at 100% Heating Air Flow Raises: ValueError– if value is not a valid valueReturns: the value of latent_effectiveness_at_100_heating_air_flow or None if not set Return type: float
-
latent_effectiveness_at_75_cooling_air_flow¶ field Latent Effectiveness at 75% Cooling Air Flow
Units: dimensionlessvalue <= 1.0Parameters: value (float) – value for IDD Field Latent Effectiveness at 75% Cooling Air Flow Raises: ValueError– if value is not a valid valueReturns: the value of latent_effectiveness_at_75_cooling_air_flow or None if not set Return type: float
-
latent_effectiveness_at_75_heating_air_flow¶ field Latent Effectiveness at 75% Heating Air Flow
Units: dimensionlessvalue <= 1.0Parameters: value (float) – value for IDD Field Latent Effectiveness at 75% Heating Air Flow Raises: ValueError– if value is not a valid valueReturns: the value of latent_effectiveness_at_75_heating_air_flow or None if not set Return type: float
-
name¶ field Name
Parameters: value (str) – value for IDD Field Name Raises: ValueError– if value is not a valid valueReturns: the value of name or None if not set Return type: str
-
nominal_electric_power¶ field Nominal Electric Power
Units: WIP-Units: WParameters: value (float) – value for IDD Field Nominal Electric Power Raises: ValueError– if value is not a valid valueReturns: the value of nominal_electric_power or None if not set Return type: float
-
nominal_supply_air_flow_rate¶ field Nominal Supply Air Flow Rate
Units: m3/sParameters: value (float or “Autosize”) – value for IDD Field Nominal Supply Air Flow Rate Raises: ValueError– if value is not a valid valueReturns: the value of nominal_supply_air_flow_rate or None if not set Return type: float or “Autosize”
-
rate_of_defrost_time_fraction_increase¶ field Rate of Defrost Time Fraction Increase
Rate of increase in defrost time fraction as actual temp falls below threshold temperature.This field only used for exhaust air recirc and exhaust-only frost control types.Units: 1/KDefault value: 0.012Parameters: value (float) – value for IDD Field Rate of Defrost Time Fraction Increase Raises: ValueError– if value is not a valid valueReturns: the value of rate_of_defrost_time_fraction_increase or None if not set Return type: float
-
sensible_effectiveness_at_100_cooling_air_flow¶ field Sensible Effectiveness at 100% Cooling Air Flow
Units: dimensionlessvalue <= 1.0Parameters: value (float) – value for IDD Field Sensible Effectiveness at 100% Cooling Air Flow Raises: ValueError– if value is not a valid valueReturns: the value of sensible_effectiveness_at_100_cooling_air_flow or None if not set Return type: float
-
sensible_effectiveness_at_100_heating_air_flow¶ field Sensible Effectiveness at 100% Heating Air Flow
Units: dimensionlessvalue <= 1.0Parameters: value (float) – value for IDD Field Sensible Effectiveness at 100% Heating Air Flow Raises: ValueError– if value is not a valid valueReturns: the value of sensible_effectiveness_at_100_heating_air_flow or None if not set Return type: float
-
sensible_effectiveness_at_75_cooling_air_flow¶ field Sensible Effectiveness at 75% Cooling Air Flow
Units: dimensionlessvalue <= 1.0Parameters: value (float) – value for IDD Field Sensible Effectiveness at 75% Cooling Air Flow Raises: ValueError– if value is not a valid valueReturns: the value of sensible_effectiveness_at_75_cooling_air_flow or None if not set Return type: float
-
sensible_effectiveness_at_75_heating_air_flow¶ field Sensible Effectiveness at 75% Heating Air Flow
Units: dimensionlessvalue <= 1.0Parameters: value (float) – value for IDD Field Sensible Effectiveness at 75% Heating Air Flow Raises: ValueError– if value is not a valid valueReturns: the value of sensible_effectiveness_at_75_heating_air_flow or None if not set Return type: float
-
supply_air_inlet_node_name¶ field Supply Air Inlet Node Name
Parameters: value (str) – value for IDD Field Supply Air Inlet Node Name Raises: ValueError– if value is not a valid valueReturns: the value of supply_air_inlet_node_name or None if not set Return type: str
-
supply_air_outlet_node_name¶ field Supply Air Outlet Node Name
Parameters: value (str) – value for IDD Field Supply Air Outlet Node Name Raises: ValueError– if value is not a valid valueReturns: the value of supply_air_outlet_node_name or None if not set Return type: str
-
supply_air_outlet_temperature_control¶ field Supply Air Outlet Temperature Control
Default value: NoParameters: value (str) – value for IDD Field Supply Air Outlet Temperature Control Raises: ValueError– if value is not a valid valueReturns: the value of supply_air_outlet_temperature_control or None if not set Return type: str
-
threshold_temperature¶ field Threshold Temperature
Supply (outdoor) air inlet temp threshold for exhaust air recirculation andexhaust only frost control types. Exhaust air outlet threshold Temperature forminimum exhaust temperature frost control type.Units: CDefault value: 1.7Parameters: value (float) – value for IDD Field Threshold Temperature Raises: ValueError– if value is not a valid valueReturns: the value of threshold_temperature or None if not set Return type: float
-
-
class
pyidf.heat_recovery.HeatExchangerDesiccantBalancedFlow¶ Bases:
pyidf.helper.DataObjectCorresponds to IDD object HeatExchanger:Desiccant:BalancedFlow This object models a balanced desiccant heat exchanger. The heat exchanger transfers both sensible and latent energy between the process and regeneration air streams. The air flow rate and face velocity are assumed to be the same on both the process and regeneration sides of the heat exchanger.
-
availability_schedule_name¶ field Availability Schedule Name
Availability schedule name for this system. Schedule value > 0 means the system is available.If this field is blank, the system is always available.Parameters: value (str) – value for IDD Field Availability Schedule Name Raises: ValueError– if value is not a valid valueReturns: the value of availability_schedule_name or None if not set Return type: str
-
economizer_lockout¶ field Economizer Lockout
Yes means that the heat exchanger will be locked out (off)when the economizer is operating or high humidity control is activeDefault value: NoParameters: value (str) – value for IDD Field Economizer Lockout Raises: ValueError– if value is not a valid valueReturns: the value of economizer_lockout or None if not set Return type: str
-
heat_exchanger_performance_name¶ field Heat Exchanger Performance Name
Parameters: value (str) – value for IDD Field Heat Exchanger Performance Name Raises: ValueError– if value is not a valid valueReturns: the value of heat_exchanger_performance_name or None if not set Return type: str
-
heat_exchanger_performance_object_type¶ field Heat Exchanger Performance Object Type
Default value: HeatExchanger:Desiccant:BalancedFlow:PerformanceDataType1Parameters: value (str) – value for IDD Field Heat Exchanger Performance Object Type Raises: ValueError– if value is not a valid valueReturns: the value of heat_exchanger_performance_object_type or None if not set Return type: str
-
name¶ field Name
Parameters: value (str) – value for IDD Field Name Raises: ValueError– if value is not a valid valueReturns: the value of name or None if not set Return type: str
-
process_air_inlet_node_name¶ field Process Air Inlet Node Name
Parameters: value (str) – value for IDD Field Process Air Inlet Node Name Raises: ValueError– if value is not a valid valueReturns: the value of process_air_inlet_node_name or None if not set Return type: str
-
process_air_outlet_node_name¶ field Process Air Outlet Node Name
Parameters: value (str) – value for IDD Field Process Air Outlet Node Name Raises: ValueError– if value is not a valid valueReturns: the value of process_air_outlet_node_name or None if not set Return type: str
-
regeneration_air_inlet_node_name¶ field Regeneration Air Inlet Node Name
Parameters: value (str) – value for IDD Field Regeneration Air Inlet Node Name Raises: ValueError– if value is not a valid valueReturns: the value of regeneration_air_inlet_node_name or None if not set Return type: str
-
regeneration_air_outlet_node_name¶ field Regeneration Air Outlet Node Name
Parameters: value (str) – value for IDD Field Regeneration Air Outlet Node Name Raises: ValueError– if value is not a valid valueReturns: the value of regeneration_air_outlet_node_name or None if not set Return type: str
-
-
class
pyidf.heat_recovery.HeatExchangerDesiccantBalancedFlowPerformanceDataType1¶ Bases:
pyidf.helper.DataObjectCorresponds to IDD object HeatExchanger:Desiccant:BalancedFlow:PerformanceDataType1 RTO = B1 + B2*RWI + B3*RTI + B4*(RWI/RTI) + B5*PWI + B6*PTI + B7*(PWI/PTI) + B8*RFV RWO = C1 + C2*RWI + C3*RTI + C4*(RWI/RTI) + C5*PWI + C6*PTI + C7*(PWI/PTI) + C8*RFV where, RTO = Dry-bulb temperature of the regeneration outlet air (C) RWO = Humidity ratio of the regeneration outlet air (kgWater/kgDryAir) RWI = Humidity ratio of the regeneration inlet air (kgWater/kgDryAir) RTI = Dry-bulb temperature of the regeneration inlet air (C) PWI = Humidity ratio of the process inlet air (kgWater/kgDryAir) PTI = Dry-bulb temperature of the process inlet air (C) RFV = Regeneration Face Velocity (m/s)
-
humidity_ratio_equation_coefficient_1¶ field Humidity Ratio Equation Coefficient 1
Parameters: value (float) – value for IDD Field Humidity Ratio Equation Coefficient 1 Raises: ValueError– if value is not a valid valueReturns: the value of humidity_ratio_equation_coefficient_1 or None if not set Return type: float
-
humidity_ratio_equation_coefficient_2¶ field Humidity Ratio Equation Coefficient 2
Parameters: value (float) – value for IDD Field Humidity Ratio Equation Coefficient 2 Raises: ValueError– if value is not a valid valueReturns: the value of humidity_ratio_equation_coefficient_2 or None if not set Return type: float
-
humidity_ratio_equation_coefficient_3¶ field Humidity Ratio Equation Coefficient 3
Parameters: value (float) – value for IDD Field Humidity Ratio Equation Coefficient 3 Raises: ValueError– if value is not a valid valueReturns: the value of humidity_ratio_equation_coefficient_3 or None if not set Return type: float
-
humidity_ratio_equation_coefficient_4¶ field Humidity Ratio Equation Coefficient 4
Parameters: value (float) – value for IDD Field Humidity Ratio Equation Coefficient 4 Raises: ValueError– if value is not a valid valueReturns: the value of humidity_ratio_equation_coefficient_4 or None if not set Return type: float
-
humidity_ratio_equation_coefficient_5¶ field Humidity Ratio Equation Coefficient 5
Parameters: value (float) – value for IDD Field Humidity Ratio Equation Coefficient 5 Raises: ValueError– if value is not a valid valueReturns: the value of humidity_ratio_equation_coefficient_5 or None if not set Return type: float
-
humidity_ratio_equation_coefficient_6¶ field Humidity Ratio Equation Coefficient 6
Parameters: value (float) – value for IDD Field Humidity Ratio Equation Coefficient 6 Raises: ValueError– if value is not a valid valueReturns: the value of humidity_ratio_equation_coefficient_6 or None if not set Return type: float
-
humidity_ratio_equation_coefficient_7¶ field Humidity Ratio Equation Coefficient 7
Parameters: value (float) – value for IDD Field Humidity Ratio Equation Coefficient 7 Raises: ValueError– if value is not a valid valueReturns: the value of humidity_ratio_equation_coefficient_7 or None if not set Return type: float
-
humidity_ratio_equation_coefficient_8¶ field Humidity Ratio Equation Coefficient 8
Parameters: value (float) – value for IDD Field Humidity Ratio Equation Coefficient 8 Raises: ValueError– if value is not a valid valueReturns: the value of humidity_ratio_equation_coefficient_8 or None if not set Return type: float
-
maximum_process_inlet_air_humidity_ratio_for_humidity_ratio_equation¶ field Maximum Process Inlet Air Humidity Ratio for Humidity Ratio Equation
Units: kgWater/kgDryAirvalue <= 1.0Parameters: value (float) – value for IDD Field Maximum Process Inlet Air Humidity Ratio for Humidity Ratio Equation Raises: ValueError– if value is not a valid valueReturns: the value of maximum_process_inlet_air_humidity_ratio_for_humidity_ratio_equation or None if not set Return type: float
-
maximum_process_inlet_air_humidity_ratio_for_temperature_equation¶ field Maximum Process Inlet Air Humidity Ratio for Temperature Equation
Units: kgWater/kgDryAirvalue <= 1.0Parameters: value (float) – value for IDD Field Maximum Process Inlet Air Humidity Ratio for Temperature Equation Raises: ValueError– if value is not a valid valueReturns: the value of maximum_process_inlet_air_humidity_ratio_for_temperature_equation or None if not set Return type: float
-
maximum_process_inlet_air_relative_humidity_for_humidity_ratio_equation¶ field Maximum Process Inlet Air Relative Humidity for Humidity Ratio Equation
Units: percentvalue <= 100.0Parameters: value (float) – value for IDD Field Maximum Process Inlet Air Relative Humidity for Humidity Ratio Equation Raises: ValueError– if value is not a valid valueReturns: the value of maximum_process_inlet_air_relative_humidity_for_humidity_ratio_equation or None if not set Return type: float
-
maximum_process_inlet_air_relative_humidity_for_temperature_equation¶ field Maximum Process Inlet Air Relative Humidity for Temperature Equation
Units: percentvalue <= 100.0Parameters: value (float) – value for IDD Field Maximum Process Inlet Air Relative Humidity for Temperature Equation Raises: ValueError– if value is not a valid valueReturns: the value of maximum_process_inlet_air_relative_humidity_for_temperature_equation or None if not set Return type: float
-
maximum_process_inlet_air_temperature_for_humidity_ratio_equation¶ field Maximum Process Inlet Air Temperature for Humidity Ratio Equation
Units: CParameters: value (float) – value for IDD Field Maximum Process Inlet Air Temperature for Humidity Ratio Equation Raises: ValueError– if value is not a valid valueReturns: the value of maximum_process_inlet_air_temperature_for_humidity_ratio_equation or None if not set Return type: float
-
maximum_process_inlet_air_temperature_for_temperature_equation¶ field Maximum Process Inlet Air Temperature for Temperature Equation
Units: CParameters: value (float) – value for IDD Field Maximum Process Inlet Air Temperature for Temperature Equation Raises: ValueError– if value is not a valid valueReturns: the value of maximum_process_inlet_air_temperature_for_temperature_equation or None if not set Return type: float
-
maximum_regeneration_air_velocity_for_humidity_ratio_equation¶ field Maximum Regeneration Air Velocity for Humidity Ratio Equation
Units: m/sParameters: value (float) – value for IDD Field Maximum Regeneration Air Velocity for Humidity Ratio Equation Raises: ValueError– if value is not a valid valueReturns: the value of maximum_regeneration_air_velocity_for_humidity_ratio_equation or None if not set Return type: float
-
maximum_regeneration_air_velocity_for_temperature_equation¶ field Maximum Regeneration Air Velocity for Temperature Equation
Units: m/sParameters: value (float) – value for IDD Field Maximum Regeneration Air Velocity for Temperature Equation Raises: ValueError– if value is not a valid valueReturns: the value of maximum_regeneration_air_velocity_for_temperature_equation or None if not set Return type: float
-
maximum_regeneration_inlet_air_humidity_ratio_for_humidity_ratio_equation¶ field Maximum Regeneration Inlet Air Humidity Ratio for Humidity Ratio Equation
Units: kgWater/kgDryAirvalue <= 1.0Parameters: value (float) – value for IDD Field Maximum Regeneration Inlet Air Humidity Ratio for Humidity Ratio Equation Raises: ValueError– if value is not a valid valueReturns: the value of maximum_regeneration_inlet_air_humidity_ratio_for_humidity_ratio_equation or None if not set Return type: float
-
maximum_regeneration_inlet_air_humidity_ratio_for_temperature_equation¶ field Maximum Regeneration Inlet Air Humidity Ratio for Temperature Equation
Units: kgWater/kgDryAirvalue <= 1.0Parameters: value (float) – value for IDD Field Maximum Regeneration Inlet Air Humidity Ratio for Temperature Equation Raises: ValueError– if value is not a valid valueReturns: the value of maximum_regeneration_inlet_air_humidity_ratio_for_temperature_equation or None if not set Return type: float
-
maximum_regeneration_inlet_air_relative_humidity_for_humidity_ratio_equation¶ field Maximum Regeneration Inlet Air Relative Humidity for Humidity Ratio Equation
Units: percentvalue <= 100.0Parameters: value (float) – value for IDD Field Maximum Regeneration Inlet Air Relative Humidity for Humidity Ratio Equation Raises: ValueError– if value is not a valid valueReturns: the value of maximum_regeneration_inlet_air_relative_humidity_for_humidity_ratio_equation or None if not set Return type: float
-
maximum_regeneration_inlet_air_relative_humidity_for_temperature_equation¶ field Maximum Regeneration Inlet Air Relative Humidity for Temperature Equation
Units: percentvalue <= 100.0Parameters: value (float) – value for IDD Field Maximum Regeneration Inlet Air Relative Humidity for Temperature Equation Raises: ValueError– if value is not a valid valueReturns: the value of maximum_regeneration_inlet_air_relative_humidity_for_temperature_equation or None if not set Return type: float
-
maximum_regeneration_inlet_air_temperature_for_humidity_ratio_equation¶ field Maximum Regeneration Inlet Air Temperature for Humidity Ratio Equation
Units: CParameters: value (float) – value for IDD Field Maximum Regeneration Inlet Air Temperature for Humidity Ratio Equation Raises: ValueError– if value is not a valid valueReturns: the value of maximum_regeneration_inlet_air_temperature_for_humidity_ratio_equation or None if not set Return type: float
-
maximum_regeneration_inlet_air_temperature_for_temperature_equation¶ field Maximum Regeneration Inlet Air Temperature for Temperature Equation
Units: CParameters: value (float) – value for IDD Field Maximum Regeneration Inlet Air Temperature for Temperature Equation Raises: ValueError– if value is not a valid valueReturns: the value of maximum_regeneration_inlet_air_temperature_for_temperature_equation or None if not set Return type: float
-
maximum_regeneration_outlet_air_humidity_ratio_for_humidity_ratio_equation¶ field Maximum Regeneration Outlet Air Humidity Ratio for Humidity Ratio Equation
Units: kgWater/kgDryAirvalue <= 1.0Parameters: value (float) – value for IDD Field Maximum Regeneration Outlet Air Humidity Ratio for Humidity Ratio Equation Raises: ValueError– if value is not a valid valueReturns: the value of maximum_regeneration_outlet_air_humidity_ratio_for_humidity_ratio_equation or None if not set Return type: float
-
maximum_regeneration_outlet_air_temperature_for_temperature_equation¶ field Maximum Regeneration Outlet Air Temperature for Temperature Equation
Units: CParameters: value (float) – value for IDD Field Maximum Regeneration Outlet Air Temperature for Temperature Equation Raises: ValueError– if value is not a valid valueReturns: the value of maximum_regeneration_outlet_air_temperature_for_temperature_equation or None if not set Return type: float
-
minimum_process_inlet_air_humidity_ratio_for_humidity_ratio_equation¶ field Minimum Process Inlet Air Humidity Ratio for Humidity Ratio Equation
Units: kgWater/kgDryAirvalue <= 1.0Parameters: value (float) – value for IDD Field Minimum Process Inlet Air Humidity Ratio for Humidity Ratio Equation Raises: ValueError– if value is not a valid valueReturns: the value of minimum_process_inlet_air_humidity_ratio_for_humidity_ratio_equation or None if not set Return type: float
-
minimum_process_inlet_air_humidity_ratio_for_temperature_equation¶ field Minimum Process Inlet Air Humidity Ratio for Temperature Equation
Units: kgWater/kgDryAirvalue <= 1.0Parameters: value (float) – value for IDD Field Minimum Process Inlet Air Humidity Ratio for Temperature Equation Raises: ValueError– if value is not a valid valueReturns: the value of minimum_process_inlet_air_humidity_ratio_for_temperature_equation or None if not set Return type: float
-
minimum_process_inlet_air_relative_humidity_for_humidity_ratio_equation¶ field Minimum Process Inlet Air Relative Humidity for Humidity Ratio Equation
Units: percentvalue <= 100.0Parameters: value (float) – value for IDD Field Minimum Process Inlet Air Relative Humidity for Humidity Ratio Equation Raises: ValueError– if value is not a valid valueReturns: the value of minimum_process_inlet_air_relative_humidity_for_humidity_ratio_equation or None if not set Return type: float
-
minimum_process_inlet_air_relative_humidity_for_temperature_equation¶ field Minimum Process Inlet Air Relative Humidity for Temperature Equation
Units: percentvalue <= 100.0Parameters: value (float) – value for IDD Field Minimum Process Inlet Air Relative Humidity for Temperature Equation Raises: ValueError– if value is not a valid valueReturns: the value of minimum_process_inlet_air_relative_humidity_for_temperature_equation or None if not set Return type: float
-
minimum_process_inlet_air_temperature_for_humidity_ratio_equation¶ field Minimum Process Inlet Air Temperature for Humidity Ratio Equation
Units: CParameters: value (float) – value for IDD Field Minimum Process Inlet Air Temperature for Humidity Ratio Equation Raises: ValueError– if value is not a valid valueReturns: the value of minimum_process_inlet_air_temperature_for_humidity_ratio_equation or None if not set Return type: float
-
minimum_process_inlet_air_temperature_for_temperature_equation¶ field Minimum Process Inlet Air Temperature for Temperature Equation
Units: CParameters: value (float) – value for IDD Field Minimum Process Inlet Air Temperature for Temperature Equation Raises: ValueError– if value is not a valid valueReturns: the value of minimum_process_inlet_air_temperature_for_temperature_equation or None if not set Return type: float
-
minimum_regeneration_air_velocity_for_humidity_ratio_equation¶ field Minimum Regeneration Air Velocity for Humidity Ratio Equation
Units: m/sParameters: value (float) – value for IDD Field Minimum Regeneration Air Velocity for Humidity Ratio Equation Raises: ValueError– if value is not a valid valueReturns: the value of minimum_regeneration_air_velocity_for_humidity_ratio_equation or None if not set Return type: float
-
minimum_regeneration_air_velocity_for_temperature_equation¶ field Minimum Regeneration Air Velocity for Temperature Equation
Units: m/sParameters: value (float) – value for IDD Field Minimum Regeneration Air Velocity for Temperature Equation Raises: ValueError– if value is not a valid valueReturns: the value of minimum_regeneration_air_velocity_for_temperature_equation or None if not set Return type: float
-
minimum_regeneration_inlet_air_humidity_ratio_for_humidity_ratio_equation¶ field Minimum Regeneration Inlet Air Humidity Ratio for Humidity Ratio Equation
Units: kgWater/kgDryAirvalue <= 1.0Parameters: value (float) – value for IDD Field Minimum Regeneration Inlet Air Humidity Ratio for Humidity Ratio Equation Raises: ValueError– if value is not a valid valueReturns: the value of minimum_regeneration_inlet_air_humidity_ratio_for_humidity_ratio_equation or None if not set Return type: float
-
minimum_regeneration_inlet_air_humidity_ratio_for_temperature_equation¶ field Minimum Regeneration Inlet Air Humidity Ratio for Temperature Equation
Units: kgWater/kgDryAirvalue <= 1.0Parameters: value (float) – value for IDD Field Minimum Regeneration Inlet Air Humidity Ratio for Temperature Equation Raises: ValueError– if value is not a valid valueReturns: the value of minimum_regeneration_inlet_air_humidity_ratio_for_temperature_equation or None if not set Return type: float
-
minimum_regeneration_inlet_air_relative_humidity_for_humidity_ratio_equation¶ field Minimum Regeneration Inlet Air Relative Humidity for Humidity Ratio Equation
Units: percentvalue <= 100.0Parameters: value (float) – value for IDD Field Minimum Regeneration Inlet Air Relative Humidity for Humidity Ratio Equation Raises: ValueError– if value is not a valid valueReturns: the value of minimum_regeneration_inlet_air_relative_humidity_for_humidity_ratio_equation or None if not set Return type: float
-
minimum_regeneration_inlet_air_relative_humidity_for_temperature_equation¶ field Minimum Regeneration Inlet Air Relative Humidity for Temperature Equation
Units: percentvalue <= 100.0Parameters: value (float) – value for IDD Field Minimum Regeneration Inlet Air Relative Humidity for Temperature Equation Raises: ValueError– if value is not a valid valueReturns: the value of minimum_regeneration_inlet_air_relative_humidity_for_temperature_equation or None if not set Return type: float
-
minimum_regeneration_inlet_air_temperature_for_humidity_ratio_equation¶ field Minimum Regeneration Inlet Air Temperature for Humidity Ratio Equation
Units: CParameters: value (float) – value for IDD Field Minimum Regeneration Inlet Air Temperature for Humidity Ratio Equation Raises: ValueError– if value is not a valid valueReturns: the value of minimum_regeneration_inlet_air_temperature_for_humidity_ratio_equation or None if not set Return type: float
-
minimum_regeneration_inlet_air_temperature_for_temperature_equation¶ field Minimum Regeneration Inlet Air Temperature for Temperature Equation
Units: CParameters: value (float) – value for IDD Field Minimum Regeneration Inlet Air Temperature for Temperature Equation Raises: ValueError– if value is not a valid valueReturns: the value of minimum_regeneration_inlet_air_temperature_for_temperature_equation or None if not set Return type: float
-
minimum_regeneration_outlet_air_humidity_ratio_for_humidity_ratio_equation¶ field Minimum Regeneration Outlet Air Humidity Ratio for Humidity Ratio Equation
Units: kgWater/kgDryAirvalue <= 1.0Parameters: value (float) – value for IDD Field Minimum Regeneration Outlet Air Humidity Ratio for Humidity Ratio Equation Raises: ValueError– if value is not a valid valueReturns: the value of minimum_regeneration_outlet_air_humidity_ratio_for_humidity_ratio_equation or None if not set Return type: float
-
minimum_regeneration_outlet_air_temperature_for_temperature_equation¶ field Minimum Regeneration Outlet Air Temperature for Temperature Equation
Units: CParameters: value (float) – value for IDD Field Minimum Regeneration Outlet Air Temperature for Temperature Equation Raises: ValueError– if value is not a valid valueReturns: the value of minimum_regeneration_outlet_air_temperature_for_temperature_equation or None if not set Return type: float
-
name¶ field Name
Parameters: value (str) – value for IDD Field Name Raises: ValueError– if value is not a valid valueReturns: the value of name or None if not set Return type: str
-
nominal_air_face_velocity¶ field Nominal Air Face Velocity
Units: m/svalue <= 6.0Parameters: value (float or “Autosize”) – value for IDD Field Nominal Air Face Velocity Raises: ValueError– if value is not a valid valueReturns: the value of nominal_air_face_velocity or None if not set Return type: float or “Autosize”
-
nominal_air_flow_rate¶ field Nominal Air Flow Rate
Air flow rate at nominal conditions (assumed to be the same for both sidesof the heat exchanger).Units: m3/sParameters: value (float or “Autosize”) – value for IDD Field Nominal Air Flow Rate Raises: ValueError– if value is not a valid valueReturns: the value of nominal_air_flow_rate or None if not set Return type: float or “Autosize”
-
nominal_electric_power¶ field Nominal Electric Power
Parasitic electric power (e.g., desiccant wheel motor)Units: WIP-Units: WParameters: value (float) – value for IDD Field Nominal Electric Power Raises: ValueError– if value is not a valid valueReturns: the value of nominal_electric_power or None if not set Return type: float
-
temperature_equation_coefficient_1¶ field Temperature Equation Coefficient 1
Parameters: value (float) – value for IDD Field Temperature Equation Coefficient 1 Raises: ValueError– if value is not a valid valueReturns: the value of temperature_equation_coefficient_1 or None if not set Return type: float
-
temperature_equation_coefficient_2¶ field Temperature Equation Coefficient 2
Parameters: value (float) – value for IDD Field Temperature Equation Coefficient 2 Raises: ValueError– if value is not a valid valueReturns: the value of temperature_equation_coefficient_2 or None if not set Return type: float
-
temperature_equation_coefficient_3¶ field Temperature Equation Coefficient 3
Parameters: value (float) – value for IDD Field Temperature Equation Coefficient 3 Raises: ValueError– if value is not a valid valueReturns: the value of temperature_equation_coefficient_3 or None if not set Return type: float
-
temperature_equation_coefficient_4¶ field Temperature Equation Coefficient 4
Parameters: value (float) – value for IDD Field Temperature Equation Coefficient 4 Raises: ValueError– if value is not a valid valueReturns: the value of temperature_equation_coefficient_4 or None if not set Return type: float
-
temperature_equation_coefficient_5¶ field Temperature Equation Coefficient 5
Parameters: value (float) – value for IDD Field Temperature Equation Coefficient 5 Raises: ValueError– if value is not a valid valueReturns: the value of temperature_equation_coefficient_5 or None if not set Return type: float
-
temperature_equation_coefficient_6¶ field Temperature Equation Coefficient 6
Parameters: value (float) – value for IDD Field Temperature Equation Coefficient 6 Raises: ValueError– if value is not a valid valueReturns: the value of temperature_equation_coefficient_6 or None if not set Return type: float
-
temperature_equation_coefficient_7¶ field Temperature Equation Coefficient 7
Parameters: value (float) – value for IDD Field Temperature Equation Coefficient 7 Raises: ValueError– if value is not a valid valueReturns: the value of temperature_equation_coefficient_7 or None if not set Return type: float
-
temperature_equation_coefficient_8¶ field Temperature Equation Coefficient 8
Parameters: value (float) – value for IDD Field Temperature Equation Coefficient 8 Raises: ValueError– if value is not a valid valueReturns: the value of temperature_equation_coefficient_8 or None if not set Return type: float
-